This custom integration forwards Home Assistant entity values into an InfluxDB bucket used by your SOLECTRUS instance. It is tailored for the SOLECTRUS sensor keys so you can map each one to a Home Assistant entity, optionally overriding measurement and field names.

Features

  • Configure InfluxDB URL, token, organisation, and bucket directly in the config flow.
  • Map every SOLECTRUS sensor to a Home Assistant entity via the options flow; measurement/field defaults are pre-filled but can be overridden.
  • Writes are batched and sent every 5 seconds; points are deduplicated by (sensor, timestamp) (value may repeat).
  • Every 5 minutes a heartbeat re-writes the current value of each mapped entity, even if it never changed. This keeps a continuous series in InfluxDB for sensors that sit at the same value (e.g. a constant 0). Forecast and car sensors are excluded.
  • Values outside a sensor's plausible range are discarded rather than written - see Value range checks.
  • When a sensor stayed at 0 for at least 30 seconds and then resumes with a positive value, the integration inserts an extra 0 point 1 second before the resume to avoid interpolation ramps. Car sensors are excluded.
  • If InfluxDB is unreachable, points are buffered and retried with the next batch. The buffer holds up to 10,000 points; beyond that the oldest are dropped.
  • Forecast sensors (power, clear-sky power, outdoor temperature) are batched as full time series instead of a single point - see Forecast sensors.

Requirements

  • Home Assistant 2025.8 or newer
  • InfluxDB 2.x reachable from Home Assistant (URL + org + bucket + token)
  • An InfluxDB token with read and write access to the target bucket (read is used to detect existing field types so the integration matches them automatically)

InfluxDB URL

You can enter the URL with or without a scheme:

  • 192.168.1.10:8086 or influxdb.local:8086 → treated as http:// (InfluxDB usually runs on the same internal/local network as Home Assistant).
  • https://influxdb.example.com → used as-is; toggle Verify SSL certificate in the config flow to control certificate validation for that connection.

Installation

HACS

  1. Open HACS and choose ⋮ (top right) → Custom repositories
  2. Add https://github.com/solectrus/ha-integration as type Integration
  3. Search for SOLECTRUS in HACS and choose Download
  4. Restart Home Assistant

Manual

  1. Copy custom_components/solectrus into your Home Assistant config/custom_components/ folder
  2. Restart Home Assistant

Setup (in Home Assistant)

  1. Ensure the integration is installed (see Installation above).
  2. Go to Settings → Devices & services → Add integration and search for SOLECTRUS.
  3. Enter your InfluxDB connection details (URL, token, org, bucket). The integration validates access by writing a test point.
  4. Open the integration Options and map the SOLECTRUS sensor keys to the Home Assistant entities you want to forward. The options flow shows the sensors in sections, with the same groups as the sensor overview of HELIOS. A section opens by default when at least one of its sensors has an entity. At the first setup, the sections for the inverter and the grid open.

Notes:

  • This integration does not create entities; it exports values of existing entities you select in the options flow.
  • If you don't configure any mappings, no data will be written.

Data type detection

The integration determines the InfluxDB field type for each (measurement, field) pair automatically on startup:

  1. If the bucket already contains data for the field, the existing type wins (Influx freezes the field type on first write, so we have to match it).
  2. Otherwise, a curated default per sensor is used (int for power, float for SOC/temperatures, bool for connection states, string for status).

If the incoming Home Assistant state cannot be converted to the resolved type, it is skipped.

Value range checks

Most sensors have a plausible range attached. A value outside that range is discarded, not written, and a warning is logged once per sensor key:

WARNING ... Value -50 from sensor.grid_import is out of range (0..), discarded; check the sensor configuration in Home Assistant

The ranges are:

  • Power sensors (inverter, house, battery charging/discharging, heat pump, grid, wallbox, CUSTOM_*): minimum 0. A sensor that reports negative values for the opposite direction of flow therefore needs a template sensor, or must be split into separate import/export entities.
  • BATTERY_SOC and CAR_BATTERY_SOC: 0 to 100.
  • CAR_ODOMETER and CAR_RANGE: minimum 0.
  • CAR_LATITUDE: -90 to 90. CAR_LONGITUDE: -180 to 180.
  • The ranges of the CAR_* keys apply to all five cars.
  • Temperatures, status strings, and booleans are unrestricted.

Custom sensors

Besides the named keys there are 20 generic slots, CUSTOM_01 to CUSTOM_20, shown as "Consumer 1" to "Consumer 20" in the section "Custom consumers" of the options flow. They map to the measurements custom_01 … custom_20 with the field power and are meant for additional consumers your SOLECTRUS instance tracks.

Electric cars

SOLECTRUS supports up to five electric cars. Each car has six sensors:

Key Field Content
CAR_BATTERY_SOC battery_soc State of charge in %
CAR_ODOMETER odometer Odometer reading in km
CAR_RANGE range Remaining range in km
CAR_CONNECTED connected The car is connected to a wallbox or a charging station
CAR_LATITUDE latitude Latitude of the car
CAR_LONGITUDE longitude Longitude of the car

The first car uses the keys without a number and the measurement car. The cars 2 to 5 add the number to the key and to the measurement. For example, the odometer of car 2 is CAR_ODOMETER_2 with the measurement car_2. Each car has a section of its own in the options flow, "Electric car 1" to "Electric car 5".

For CAR_LATITUDE and CAR_LONGITUDE, you can select a device_tracker entity of the car. The integration then reads the attributes latitude and longitude of the entity instead of its state. One device_tracker can feed both keys.

A car sensor is a state: SOLECTRUS keeps a reading until the next one, and a parked car can send no update for days. The integration therefore writes a car sensor only when Home Assistant updates the entity, with the time of that update. The heartbeat does not repeat it, and no extra 0 point is added. A repeated reading with a new time shows an old value as current. This needs a SOLECTRUS version after v1.3.4. Version v1.3.4 treats a state of charge older than 2 hours as outdated.

At a start of Home Assistant or of the integration, the integration writes the current value of each car sensor once. This point gets the time at which Home Assistant loaded the value, which can be later than the time of the reading in the car.

Advanced options

In the first step of the options flow, you can enable Customize measurement and field. The next step then shows two more fields per sensor:

  • Measurement: override the default measurement name.
  • Field: override the default field name.

Once configured, the integration listens for entity state changes and writes them to InfluxDB following the above rules.

Forecast sensors

Three sensor keys are treated as forecast time series instead of a single current value:

  • INVERTER_POWER_FORECAST
  • INVERTER_POWER_FORECAST_CLEARSKY
  • OUTDOOR_TEMP_FORECAST

Instead of writing just the entity's current state, the integration reads the entity's forecast time series attribute (if present) and writes every entry as its own point, timestamped accordingly. This is picked up automatically - no extra configuration needed - as long as the mapped entity exposes one of the following:

  • forecast attribute (a list of {datetime/time/period_end, ...} entries) - this is what pvnode exposes on its power (watts), clear-sky (watts_clearsky), and temperature (temperature) forecast sensors.
  • detailedForecast / detailedHourly attribute - the format used by ha-solcast-solar's energy forecast sensors (period_start + pv_estimate, in kW). The kW value is automatically scaled ×1000 to match the Watt-based INVERTER_POWER_FORECAST field. Solcast has no clear-sky or temperature forecast, so only INVERTER_POWER_FORECAST is populated from it.
  • A weather.* entity for OUTDOOR_TEMP_FORECAST - the integration calls the weather.get_forecasts service (type: hourly) and writes the returned temperature series.

Not currently supported: the built-in forecast.solar integration. It doesn't expose any per-entity forecast attribute - only a config-entry-level "solar forecast" API (used by the Energy dashboard) that returns Wh energy totals, which is a different mechanism this attribute-based batching can't use.

If the mapped entity has none of the above (e.g. right after Home Assistant/the integration restarts, before the source has produced its first forecast), nothing is written for that point in time; the next update from the source is picked up automatically, including immediately on integration startup if data is already available.

Development

scripts/setup    # Install/update dependencies into .venv
scripts/test     # Run the test suite (supports pytest args, e.g. scripts/test -v)
scripts/lint     # Format and lint the codebase with ruff
scripts/develop  # Start Home Assistant with the integration loaded

scripts/deploy copies the integration to a running Home Assistant and restarts it. It needs the "Samba share" add-on and a long-lived access token. The script header names the settings.

Troubleshooting

  • Setup error "Bucket not found": ensure the bucket exists and the token has write access to it.
  • TLS/certificate errors: https:// connections verify certificates; use a valid cert/CA, use http:// for local non-TLS InfluxDB, or disable Verify SSL certificate (insecure).
  • field type conflict in InfluxDB: this should no longer happen, since the integration auto-detects the existing field type from InfluxDB on startup. If it does, check that the configured token has read access to the bucket — without read, the integration cannot inspect the schema and falls back to its built-in defaults, which may not match.

Sensor becomes unknown/unavailable

No point is written for a mapped entity while its state is unknown, unavailable, or missing entirely - the last value already in InfluxDB simply stays the latest point until the entity reports again. A warning is logged once per outage (not repeated on every 5-minute heartbeat), and an info message once the entity recovers, e.g.:

WARNING ... INVERTER_POWER (sensor.inverter_power) is unavailable; no new points will be written until it reports a value again
INFO    ... INVERTER_POWER (sensor.inverter_power) is reporting again

Debug logging

To see exactly what the integration sends to InfluxDB, enable debug logging for it in configuration.yaml and restart Home Assistant:

logger:
  logs:
    custom_components.solectrus: debug

Every point is logged right before it's written - including ones that end up failing and get retried on the next batch - so you can trace mappings back to what actually landed (or didn't) in InfluxDB:

Influx point: sensor=INVERTER_POWER_FORECAST measurement=inverter_forecast field=power value=1500 timestamp=2026-07-29T13:00:00+00:00
Influx batch write succeeded: 3 point(s) sent

About

Write data from Home Assistant to SOLECTRUS

Topics

Resources

Contributing

Stars

5 stars

Watchers

1 watching

Forks

Releases

Sponsor this project

Used by

Contributors

Languages