ADR 0003: Use an authenticated named-pipe window broker

Status

Accepted.

Context

Windows Terminal routes wt invocations to existing named windows and supports cross-window tab operations. The existing implementation uses Windows-specific remoting and C++/WinRT application infrastructure.

Decision

Use one NativeAOT process with an application broker and authenticated, current-user-only named-pipe IPC. Keep protocol messages versioned and source-generated. The broker owns windows and transferable terminal sessions; Avalonia owns UI dispatch.

Consequences

  • wt -w, global summon, and tab tear-off do not depend on WinRT remoting.
  • IPC authorization, protocol versioning, crash recovery, and stale endpoint handling become explicit test requirements.
  • The initial app can continue using one process with multiple windows until the broker phase lands.